SPL Sense
All SPL Sense features in detail: measurements, value profiles, live screen, leveler, calibration and settings.
SPL Sense is the measurement software for the sensor. It records the sound level, displays it live, rates it against
your value profile and, if required, controls the volume with the leveler. SPL Sense works without internet; with
SPL Cloud the data is additionally archived online.
This chapter is aimed at professionals. For your first measurement, the Quick start
is enough.
1 - Installation and updates
Windows, macOS and Linux, updates and where SPL Sense stores its data.
| Platform |
Operation |
| Windows |
Desktop app |
| macOS (Apple silicon and Intel) |
Desktop app |
| Linux on ARM and ARM64, e.g. Raspberry Pi |
Web server: operated in the browser, also from a tablet or phone on the same network |
The features are the same everywhere. The only exception: you can calibrate
the sensor only in the desktop app.
Installation
Open the downloaded file and follow the installer. To find out which Mac you have, go to Apple menu › About This
Mac: “Chip” means Apple chip, “Processor” means Intel.
First start
On first start, SPL Sense shows a privacy notice. Accept and Continue proceeds, Close Application closes
SPL Sense.
Updates
SPL Sense checks by itself whether a new version is available. If so, the notice Update available appears on the
overview with the buttons Update and Remind me later.
- Stop a running measurement. No update can be installed during a measurement.
- Click Update and then Update and restart.
- SPL Sense downloads the new version, installs it and restarts.
If SPL Sense does not restart by itself after the update, start it manually. After a restart, no measurement is active
unless autonomous mode is switched on.
The current version and the version history are under Settings › About.
Where the data is stored
SPL Sense stores all measurements locally on the computer:
| Platform |
Folder |
| Windows |
%AppData%\SPLSense |
| macOS |
~/Library/SPLSense |
| Linux |
~/.SPLSense |
Back up this folder regularly or switch on the Cloud Uplink for your
measurements. You back up individual measurements as .splsense files, see
Import and export.
2 - User interface and search
Status bar, device status, overview, menus and search.
Status bar
The status bar is at the top of every page:
- Logo and path: the logo leads to the overview, the path next to it back to higher-level pages.
- Device status: shows at a glance what is happening:
- Measurement running (green, with the current LAeq 1 s): a click opens the live screen.
- Measurement stopped or Sensor disconnected (red): a click opens the active measurement.
- No measurement loaded
- Connected devices: sensor, leveler and cloud connection, each with its state. If remote control from SPL Cloud is
allowed, this is shown here too.
- Search (magnifying glass), Help (question mark, opens this documentation) and Settings (gear).
Overview
The overview lists all open measurements as cards. Each card shows the state of the measurement and the values of the
last four measurement days, coloured according to the thresholds of the value profile. Below are the completed
measurements as a short list.
At the top right, New measurement creates a measurement and Import restores a backed-up measurement.
At the bottom of the overview you find the connected sensor, a connected leveler and, if available, a notice about an
update.
Measurement page
- Page header: name, state and the most important actions as buttons, for example Start or Stop. All other
actions are in the Measurement menu. Actions that change the measurement permanently (Deactivate, Complete) are at
the end of the menu.
- Live strip: while measuring, you see the 1-second values and, if active, the leveler below the page header.
- Days and chart: select a measurement day; the chart shows its course. Next to the day you find the buttons
PDF (day report) and CSV.
- Below: deviations, events, sensor and cloud uplink.
What the values and markers mean is described under Measurement data.
States of a measurement
| State |
Meaning |
| Active |
The measurement is loaded and ready. SPL Sense records as soon as you start. At most one measurement is active at any time. |
| Measurement running |
SPL Sense is recording. |
| Interrupted |
The sensor no longer delivers data, for example because it was unplugged or the computer was asleep. The measurement continues by itself as soon as the sensor delivers data again. |
| Stopped |
Recording is paused. |
| Completed |
The measurement is locked and can only be viewed, exported or re-opened. |
More under Measurements.
Search
Open the search with the magnifying glass or with Ctrl+K (Mac: ⌘+K). It
finds measurements (open and completed), settings pages, value profiles and live screens. Use the arrow keys to select a
result and Enter to open it.
You can also find settings by keywords, for example “password” for the operator PIN or “limiter” for the leveler.
Use on tablet and phone
In web server mode (Linux) you operate SPL Sense in the browser, also from a tablet or phone. The interface adapts to
small screens: the path in the status bar becomes a back link, lists are shown one below the other.
3 - Measurements
Life cycle of a measurement: create, activate, measure, edit, complete, import and export.
A measurement stands for one measuring point. It contains its settings (value profile, day boundary, offsets, leveler)
and all recorded data. A measurement can run over many days and be started and stopped as often as you like.
Flow
create / import
│
▼
open ──activate──▶ active ──Start──▶ running ──Stop──▶ active (stopped)
▲ │ │ sensor gone ▲
│ deactivate ▼ │ sensor back
└──────────────────┘ interrupted ─────────┘
│
complete ──▶ completed ──re-open──▶ open
- Activate: at most one measurement is active at any time; SPL Sense records only into it. You can only switch when
the active measurement is stopped.
- Start and stop: Start needs a connected sensor. Stop asks for confirmation. If the leveler is active,
SPL Sense points out that it will be switched off when stopping.
- Interrupted: if the sensor is unplugged or delivers no values for 20 seconds (for example because the computer was
asleep), the measurement is interrupted. When the sensor delivers data again, it continues by itself. You end an
interrupted measurement with Stop.
- Deactivate: Measurement menu › Deactivate. The measurement remains open but is no longer active.
- Restart of SPL Sense: after a restart, no measurement is active. If a measurement should continue automatically,
use autonomous mode.
Create
On the overview, New measurement:
| Field |
Meaning |
| Name |
Required. Appears on the overview, in reports and in SPL Cloud. |
| Value Profile |
A template (copied), Custom (the editor opens afterwards) or None. See Value profiles. |
| Day Boundary |
Time between 00:00 and 06:00 at which a measurement day ends. |
| Cloud Uplink |
Uploads the measurement to SPL Cloud. Only possible if SPL Sense is registered with the cloud. |
A new measurement is not yet active. Its leveler is set to SPL Tools L1 (USB) and mode Off.
Edit
Measurement menu › Edit Measurement. Possible as long as the measurement is not running, not interrupted and
not completed. You can also edit a measurement that is not active while another one is recording.
- Name, Day Boundary
- Cloud Uplink: switching it on uploads all data of the measurement, including what was already recorded.
Switching it off stops the upload; what is already in the cloud stays there.
- Offsets for A, C and Z, see below
- Value Profile: adjust it with Edit Value Profile
If you change the day boundary or value profile, SPL Sense recalculates the limits and measurement days. Every change
of the offsets and of the value profile appears in the events.
You edit the leveler settings separately; they can also be changed during the measurement.
Offsets
The offset converts the values at the measuring position to the loudest place in the audience. How to determine it is
described under Measuring point and offset.
There are two ways:
- Tune offsets (Measurement menu): with live values. Only for the active, stopped measurement with a connected
sensor. The table shows, per weighting, the current level, the highest level since Reset max values, the offset
and both values including the offset. Nothing measured here is recorded.
- Edit Measurement: enter offsets directly as numbers, for example from a measurement with a handheld meter.
A changed offset applies from the next start. Data already recorded keeps the offset it was recorded with.
Complete and re-open
When the event is over, complete the measurement: Measurement menu › Complete measurement. The measurement must
be stopped. After that it is locked: it can no longer be activated, edited or started, but it can be viewed and
exported. If autonomous mode is set to this measurement, it is switched off.
You re-open a completed measurement in the menu with Re-open measurement.
Deleting
You delete an open measurement under Edit Measurement › Delete measurement, a completed one in the
Measurement menu. It is only deleted on this computer; what is in SPL Cloud stays there. How to delete the
measurement in the cloud as well is described under
Measurements in the cloud.
Import and export
A measurement can be backed up as an .splsense file and read in again on another computer, with all data and
settings.
- Export: complete the measurement and click Export measurement.
- Import: on the overview, Import, then drag the file into the field. If the measurement already exists, you
can replace it with Overwrite existing measurement.
You export the values as a table in CSV format, see Measurement data.
4 - Measurement data
Days, chart, interval details, deviations, events, comments, excluded time ranges and reports.
The measurement page looks the same in SPL Sense and in SPL Cloud. What is described here applies to both; differences
in the reports are listed at the end.
Measurement days and chart
The data is organized by measurement days; a measurement day ends at the measurement’s day boundary. Each day shows the
values of the value profile, coloured according to the thresholds: yellow for Notification, orange for Warning,
red for Limit. Show all days displays older days.
The chart shows the course of the selected day:
- the values of the value profile as lines, the rating as a coloured band
- comments and events as markers
- excluded time ranges greyed out
- with an active leveler, also the signal level (line), the gain reduction and the correlation
The first values appear after the first full minute of recording.
Interval details
A click into the chart opens the details of the minute at that point (an interval): all values, the spectrum in
third-octave bands and the check results. Use the arrows to move to the previous or next minute.
| Indication |
Meaning |
| Signature valid |
The data is unchanged since the sensor signed it. |
| Signature invalid / Validation block missing |
The data cannot be proven to be unchanged. |
| Calibration expired |
The data was recorded with an expired calibration. |
| Clip |
The level was too high for the sensor (overload). The values of this minute are not reliable. |
| Low Values |
The level was below the sensor’s measuring range. |
| Temperature |
The sensor was too hot. |
| Voltage |
The sensor’s supply voltage was too low. |
| Weather Protection |
The compensation filter for the weather protection was switched on. |
| Multiple Sensors Used |
The sensor was changed in this minute. |
Deviations
The Deviations section lists, per value of the value profile, when the selected day exceeded a threshold, with the
highest value. A click on an entry draws the thresholds into the chart.
Events
The Events section lists everything that happened with the measurement, newest first:
- recording started and stopped, with reason (for example manually, autonomous mode, microphone disconnected, sleep
mode, sensor reconnected)
- measurement created, activated, completed, re-opened
- offsets, value profile and leveler settings changed, each with the old and new values
- leveler bypassed and re-enabled
- comments and changed excluded time ranges
If a change came via SPL Cloud or the API, this is indicated; for the cloud, also by whom.
With Add › Add comment in the Events section you record something at a point in time, for example “Encore” or
“Offset checked with handheld meter”. Comments appear in the chart and can be edited later. For a completed
measurement, comments are only possible up to the time of completion.
Excluding time ranges
Some periods should not be included in the rating, for example tuning the system with pink noise before doors open.
With Add › Exclude a time range you define such a range with From, To and a comment.
An excluded range:
- is greyed out in the chart and marked Not counted
- does not count for maxima, the rating according to the value profile and the deviations
- is kept with all measurement data
Count again? removes the exclusion. Every change appears in the events.
Reports and exports
| What |
Where |
| Day report (PDF) of the selected day |
PDF button next to the day |
| CSV of the selected day |
CSV button next to the day |
| CSV of the whole measurement |
Measurement menu › Export all measurement days to CSV |
| whole measurement as a backup |
Export measurement, see Measurements |
In SPL Cloud, the day report (also with deviations) and a pictures report are available with
Pro.
Cloud uplink
If the cloud uplink is switched on, the measurement page shows the upload status: Online, Offline and how many
intervals, events and leveler statistics are still waiting for upload. Without internet, SPL Sense keeps measuring
normally and catches up with the upload.
5 - Value profiles
Which values are calculated, with which thresholds, and the built-in templates.
A value profile defines which values a measurement calculates and from when they count as too loud. It determines the
colours on the overview and in the chart, the deviations and the alarms in SPL Cloud.
Structure
A value profile consists of one or more values. Each value has:
| Part |
Options |
| Integration Type |
Leq (equivalent continuous level) or MaxF (highest level with time weighting Fast) |
| Weighting |
A, C or Z |
| Time |
1 to 60 minutes |
| Notification, Warning, Limit |
thresholds in dB, each optional |
Examples: Leq, A, 60 minutes gives LAeq 60′; MaxF, C, 1 minute gives LCFmax 1′.
Averages are calculated as moving averages: LAeq 60′ is, at every minute, the average over the preceding 60 minutes,
also across the day boundary and across pauses. A value counts as above the threshold if it exceeds it; exactly equal is
still fine.
Built-in templates
SPL Sense provides templates for Switzerland (V-NISSG) and Germany (DIN 15905-5). The values are listed under
Templates for V-NISSG and DIN 15905-5. Built-in templates cannot be
changed.
Your own templates
Under Settings › Value Profiles › Create you create your own templates:
- Enter a Name.
- Add the values you need with Add Value and set the thresholds.
- Click Save.
You can change or delete your own templates at any time. Measurements that use a template are not affected: the template
is copied into the measurement when it is created.
Changing the value profile of a measurement
Measurement menu › Edit Measurement › Edit Value Profile. Here you choose another template or adjust the
values directly. If the profile differs from its template, SPL Sense indicates this; Reset profile to template values
restores the template’s values.
When saving, SPL Sense recalculates all previous measurement days with the new profile. The measurement data itself does
not change. The change appears in the events with the old and new profile.
6 - Live screen and kiosk
Live screen, built-in and custom screens, widgets and kiosk mode.
The Live Screen shows the current values large and easy to read, for example on a second display for the DJ or the
technicians. You open it on the measurement page with Live Screen or by clicking the device status in the status bar.
Choosing a screen
Choose the screen at the top right of the live screen. SPL Sense remembers per measurement which one was used last.
Screens for common cases are built in, each with and without leveler display:
| Screen |
Content |
| VNISSG 93dBA, 96dBA, 100dBA |
LAeq 3 s, LAeq 5′, LAeq 60′, LAFmax, history of the last hour |
| DIN 15905-5 |
LAeq 5 s, LAeq 5′, LAeq 30′, LCFmax, history of the last hour |
| DJ |
LAeq 3 s and LAeq 5′, reduced to the essentials |
| … Leveler |
additionally gain reduction and correlation |
Custom screens
Under Settings › Live Screens › Create:
- Enter a Name.
- Add widgets with Add.
- Arrange them on the grid: drag a widget to move it and its corner to resize it. With the keyboard: arrow keys move,
Shift + arrow keys resize.
- Select a widget to change its type or set its Color Thresholds.
- Save.
The preview shows placeholder values at real size, so you can see how large the numbers will be. On narrow screens the
widgets are stacked.
| Group |
Widgets |
| Numeric SPL |
Leq or MaxF, weighting A, C or Z, over Current or 3 s to 60 min |
| Graph |
Spectrum, History Today, History Last Hour |
| Leveler |
Gain Reduction, Correlation |
| Other |
Last Interval |
Color thresholds
Numeric widgets change colour when a value exceeds a threshold. You set the thresholds manually or take them from the
measurement with From value profile. This only works for times above one minute, because the value profile knows no
shorter times.
Full screen and kiosk
Full screen switches the live screen to kiosk mode: instead of menus, a slim bar shows only measurement, screen, time
of the last value and device status. The widgets fill the whole screen, even on a large TV. Leave full screen returns.
If an operator PIN is set, SPL Sense asks for it when leaving the live screen
and full screen. This way nobody at the DJ booth can change the settings.
For devices that should start directly into the live screen, see
SPL Sense for Linux › Operation.
7 - Leveler
Automatic level control with the SPL Tools L1 or an audio processor: variants, modes, calibration and operation.
The leveler automatically keeps the level below a limit. SPL Sense measures the sound level with the sensor, receives
from the leveler device the level of the signal it is currently outputting (line level), and calculates how much the
volume must be reduced (gain reduction). The leveler device applies the reduction in the signal path.
The leveler belongs to the measurement: each measurement has its own leveler settings. You find them in the
Measurement menu › Leveler Settings.
Variants
| Connection |
When |
| SPL Tools L1 (USB) |
The L1 is connected via USB to the computer running SPL Sense. Default for new measurements. |
| SPL Tools L1 (network) |
The L1 is located elsewhere, for example in the rack next to the amplifier, and can be reached via Ethernet or WiFi. |
| External audio processor (SenseAPI) |
An audio processor with an SPL Sense plugin queries SPL Sense via the API. |
For Q-SYS there is the plugin SPL Sense Leveler: download. Add it to
your Q-SYS design and enter the IP address of the computer running SPL Sense, the port and the API key in the plugin. In
SPL Sense, under Settings › API, the mode External Leveler Only or Full Control must be switched on, see
SPL Sense API. If the settings are correct, the plugin shows the state and
the measured values of SPL Sense.
Connect the L1 via USB. In the measurement’s leveler settings, Leveler Connection then shows Connected with
type, serial number and firmware.
- Choose SPL Tools L1 (network).
- Enter the name or IP address of the L1 under Host, or click Search: SPL Sense then looks for L1 devices on
the local network.
- Enter the API Key of the L1.
- Choose the Security:
- HTTP (L1 TLS off): unencrypted, only in protected local networks
- HTTPS, pinned certificate: encrypted with the L1’s own certificate. Read the fingerprint with
Read from L1 and compare it with the one shown on the L1.
- HTTPS, trusted CA: encrypted with a certificate from a recognized authority
- Click Test connection and then Save.
The easiest way is Set up from L1 on USB: plug the L1 in via USB once, and SPL Sense takes over host, API key,
security and fingerprint. If the L1 has no API key yet, SPL Sense generates one.
After several wrong API keys, the L1 blocks the connection for 30 seconds.
Setting up the L1 itself
When an L1 is connected via USB, you set it up under Settings › Leveler:
- Device Information: type, serial number, firmware, MAC addresses
- Ethernet Configuration: automatic or static with IP address, netmask and gateway
- WiFi Configuration: network and password. The L1 only supports 2.4 GHz networks. The status shows the connection
and signal strength.
- Network API: hostname, API key (empty: leveling over the network off; Generate creates one), admin password
for the L1’s web interface and the encryption (Off, Self-signed certificate, Custom certificate)
Limits and mode do not belong here but in the measurement’s leveler settings.
Modes
| Mode |
Behaviour |
| Off |
No leveling. |
| Plain leveler |
Always controls slowly and smoothly. |
| Leveler with panic |
Like the plain leveler, but reduces quickly if the level suddenly rises well above the limit. |
| Leveler with panic and audience compensation |
In addition, SPL Sense detects which part of the level does not come from the sound system (for example the audience) and only controls the share of the sound system. Requires a calibrated line offset. |
Background on audience compensation: Audience noise.
Limits
Under Limit Values you enter a limit between 40 and 140 dB for each of A, C and Z. An empty field means: this
weighting is not controlled. If several limits are set, the weighting that requires the greatest reduction applies; it
is called dominant.
The leveler controls to an average over about 10 seconds. The gain reduction is at most 40 dB.
Calibrating the line offset
Only for the mode with audience compensation. The line offset is the difference between the level at the sensor and the
line level when only the sound system is playing. Before calibrating, the measurement must be active and stopped, the
sensor connected and the leveler mode saved or applied (Apply settings).
- Play pink noise through the entire signal chain, as loud as during the event. If a DJ mixer is the source, feed
the noise into the DJ mixer.
- Make sure it is quiet: no audience, no conversations, no other sources.
- Click Capture Line Offset. SPL Sense measures for three seconds and enters the line offset for A, C and Z.
- Check the Correlation: it should be as close as possible to 1.000 for all weightings. Otherwise repeat the
measurement.
- Save.
Important
After calibrating, nothing may change the level between the leveler device and the loudspeakers: no gain changes on
amplifiers or processors, no compressors or limiters in this part of the signal path. Otherwise the line offset is no
longer correct and the leveler controls incorrectly.
You can also change the line offset manually. Be careful: even a small deviation causes the leveler to ignore audience
noise or to intervene too strongly.
Reading the correlation
The correlation compares the measured level with the level the sound system alone should produce.
| Correlation |
Meaning |
| about 1.000 |
Only the sound system can be heard. |
| above 1 |
Additional noise, usually audience. |
| below 1 |
The sensor is damped, or something was changed in the sound system after calibration. |
During the measurement
When the measurement is running and the leveler is active, the live strip shows:
- the current Gain Reduction
- the Correlation per weighting; the dominant one is bold and marked with
>, for example > 0.987 @A
- the 1-second level of the dominant weighting highlighted
You can change limits, mode and line offsets during the measurement as well; they apply immediately without the gain
reduction jumping. Calibrating is only possible with the measurement stopped.
The day chart additionally shows the line level, the gain reduction and the correlation. With the cloud uplink, this
data also goes to SPL Cloud.
Warnings
| Message |
What to do |
| No contact with processor yet / since … |
Check the connection to the L1 or the audio processor. |
| Leveler is disabled because the configuration is incomplete |
At least one limit is missing, in the mode with audience compensation also the matching line offset. |
Bypass
Bypass Leveler switches the control off immediately, for example in case of a problem. Caution: the volume then
rises by the current gain reduction. With 15 dB reduction, it suddenly gets 15 dB louder.
The bypass applies to the whole device and stays on until you lift it with Reenable Leveler, even across a restart,
a change of measurement or unplugging and replugging. As long as it is active, the overview and the measurement page show
a notice.
Stop and interruption
- Stop: the leveler sets the gain reduction to 0 and releases control. SPL Sense warns when stopping if the leveler
is currently reducing.
- Interrupted (sensor gone): the last gain reduction remains until the sensor delivers data again.
Who can change what
The leveler settings can be changed for every open measurement, even without a sensor and even when it is not active.
Not for a completed measurement. From SPL Cloud, mode, limits and line offsets can be changed via
remote control, but not the connection or the calibration.
8 - Sensor and calibration
Sensor status, weather protection filter and calibration of the sensor.
Under Settings › Sensor Information (or by clicking the sensor on the overview) you see:
- Device Information: serial number, hardware revision, MCU ID, firmware version, quality check
- Voltage and MCU Temperature, refreshed with Refresh measured values
- Calibration: date, by whom, valid until
- Weather Protection: the compensation filter that is set
Always connect only one sensor to a computer running SPL Sense. If you change the sensor during a measurement
(unplug, plug in another), SPL Sense continues measuring with the new one; the affected minute is marked in the data.
Calibration status
| Display |
Meaning |
| Calibrated |
The calibration is valid. |
| Calibration expired |
The calibration has expired. You can measure, but the data is marked. |
| Calibration invalid |
The sensor has no valid calibration. |
If the calibration has expired or is invalid, SPL Sense asks for confirmation when starting the measurement
(Start anyway). If the measurement is started via autonomous mode, the API or remote control, SPL Sense does not ask.
Weather protection filter
A weather protection over the microphone slightly changes the frequency response. The compensation filter corrects
this. It must match the weather protection used:
- Enable Filter for SPL Tools W1 for the SPL Tools W1 weather protection
- Enable Filter for Weather Protection V1 for the older V1 weather protection
- Disable Filter without weather protection
The filter is stored in the sensor and applies until you change it, also for other measurements and on other computers.
You can only change it when no measurement is running. When it is switched on, the overview shows a notice and the
measurement data is marked.
Calibrating the sensor
With an authorization as a calibrator, you can calibrate sensors yourself. You need:
- SPL Sense for Windows or macOS (not available in web server mode)
- internet
- a sound calibrator with 94 or 114 dB
- a confirmation as a calibrator from SPL Tools (see below)
Applying as a calibrator
- On the sensor page, Calibrate › Apply as Calibrator.
- Fill in the online form. In it, you also describe your calibration equipment.
- SPL Tools reviews your application and confirms it by email.
As soon as you have the confirmation, you can calibrate.
Procedure
The measurement must be stopped and the sensor connected.
-
Sensor page › Calibrate › Log In. SPL Sense shows who you are logged in as and the current calibration.
-
Put the running calibrator on the sensor and wait until the level is stable.
-
Click the capture button for 94 dB or 114 dB, matching your calibrator.
-
Check the Capture Result:
- Capture drift: fluctuation during the capture
- Previous calibration drift: how far the sensor deviates since the last calibration
If the values indicate that the sensor is drifting, SPL Sense warns you. Calibrate again and check the sensor for
mechanical damage; if in doubt, send it in for inspection.
-
Choose the Signing Organization and the certificate, and fill in Calibrated For and Calibrator Device.
-
Click Sign and Store Calibration.
The calibration is digitally signed and stored in the sensor. From now on, the measurement data is signed with the new
calibration.
A sensor without a previous calibration cannot be calibrated this way. In that case, contact SPL Tools.
9 - Autonomous mode
SPL Sense starts a measurement automatically as soon as it runs.
In autonomous mode, SPL Sense activates and starts a specific measurement by itself as soon as SPL Sense starts. This is
intended for permanently installed systems, for example in a club or on a Raspberry Pi: after a power failure or
restart, the system continues measuring without intervention.
Setup
- Settings › Autonomous Mode.
- Set Automatically run a measurement when running to On.
- Choose the Measurement. Only open measurements are offered.
- Save. If SPL Sense is stopped and a sensor is connected, SPL Sense offers to start the measurement right away.
Behaviour
- When SPL Sense starts: the chosen measurement is activated and started. If no sensor is connected, the
measurement is Interrupted and starts recording as soon as the sensor is there.
- Stopping: you can stop the measurement at any time. It then stays stopped until SPL Sense starts the next time.
- Completing: when the measurement is completed, autonomous mode switches itself off.
- Calibration: with the automatic start, SPL Sense does not ask, even if the calibration has expired. The events
show the reason Automatically started as autonomous measurement.
For unattended operation
Combine autonomous mode with:
10 - Settings
Operator PIN, connection to SPL Cloud and remote control, API, language.
Open the settings with the gear at the top right. Each row shows the current state.
| Group |
Settings |
| Measuring |
Value Profiles, Live Screens, Autonomous Mode |
| Device |
Sensor Information, Leveler, Update |
| Access and connections |
Operator PIN, Cloud, API, Language |
| About |
Version, release notes, contact, privacy, open source licenses |
Operator PIN
An operator PIN protects SPL Sense against changes. Without a PIN, anyone with access to SPL Sense can change
everything.
- Settings › Operator PIN.
- Enter a New PIN (4 to 8 digits) and repeat it.
- Save.
With a PIN set:
- all pages except the live screen are locked. SPL Sense shows SPL Sense is locked and asks for the PIN.
- SPL Sense also asks for the PIN when leaving the live screen and full screen.
- the PIN applies in the app and in the browser (web server mode).
Remove PIN lifts the protection again.
SPL Cloud
Under Settings › Cloud you connect SPL Sense with SPL Cloud. A registered installation is called an
instance in the cloud.
Registering
- Register instance. SPL Sense needs internet for this.
- Open the link shown or scan the QR code with another device. The code is only valid for a short time; Get new code
gives you a new one.
- Log in to SPL Cloud and confirm the registration. Choose the Owner: you personally or an organization you are a
member of. See Organizations.
The page then shows Instance is registred with instance ID, host, owner and the connection status (Online,
Connecting…, Offline).
Which measurements go to the cloud is set per measurement with the Cloud Uplink, see
Measurements.
Unregistering
Unregister Instance disconnects SPL Sense from the cloud. The cloud uplink is switched off for all measurements;
what is already in the cloud stays there. After registering again, you switch the uplink back on per measurement.
If the page shows Authentication failed!, unregister the instance and register it again.
Allowing remote control
With Allow remote control, people with access to this instance in SPL Cloud may start and stop, switch and create
measurements and change offsets, leveler and value profile, as long as SPL Sense is online. Calibration and updates are
never possible remotely.
Remote control is off by default. When it is on, the status bar shows this, and every command from the cloud appears as
a message and in the measurement’s events, with the name of the person.
In the cloud, remote control requires SPL Cloud Pro on the
measurement.
API
The SPL Sense API lets you monitor and control SPL Sense and connect external audio processors as levelers. It is off by
default. Details under SPL Sense API.
Language
German, English, French or System Default.
About
Version, release notes (English), contact, privacy policy and the open source licenses used.