Value profiles

Which values are calculated, with which thresholds, and the built-in templates.

A value profile defines which values a measurement calculates and from when they count as too loud. It determines the colours on the overview and in the chart, the deviations and the alarms in SPL Cloud.

Structure

A value profile consists of one or more values. Each value has:

Part Options
Integration Type Leq (equivalent continuous level) or MaxF (highest level with time weighting Fast)
Weighting A, C or Z
Time 1 to 60 minutes
Notification, Warning, Limit thresholds in dB, each optional

Examples: Leq, A, 60 minutes gives LAeq 60′; MaxF, C, 1 minute gives LCFmax 1′.

Averages are calculated as moving averages: LAeq 60′ is, at every minute, the average over the preceding 60 minutes, also across the day boundary and across pauses. A value counts as above the threshold if it exceeds it; exactly equal is still fine.

Built-in templates

SPL Sense provides templates for Switzerland (V-NISSG) and Germany (DIN 15905-5). The values are listed under Templates for V-NISSG and DIN 15905-5. Built-in templates cannot be changed.

Your own templates

Under Settings › Value Profiles › Create you create your own templates:

  1. Enter a Name.
  2. Add the values you need with Add Value and set the thresholds.
  3. Click Save.

You can change or delete your own templates at any time. Measurements that use a template are not affected: the template is copied into the measurement when it is created.

Changing the value profile of a measurement

Measurement menu › Edit Measurement › Edit Value Profile. Here you choose another template or adjust the values directly. If the profile differs from its template, SPL Sense indicates this; Reset profile to template values restores the template’s values.